Review Type | Outcome | Est. Completion Date | Completed |
---|---|---|---|
Building Code Review | Approved | 10/21/2021 | 10/25/2021 |
Todd Carr
|
|||
Addendum submitted 10/14/21" RFI's approved | |||
Engineering Review | Approved | 10/04/2021 | 10/04/2021 |
Stuart King, P.E.
|
|||
Utilities Review - Mt. Werner | Approved | 10/04/2021 | 10/04/2021 |
Richard Buccino
|
|||
Planning Review | Approved | 09/14/2021 | 09/27/2021 |
Bob Keenan, AICP
|
|||
Building Code Review | Approved | 09/14/2021 | 09/27/2021 |
Todd Carr
|
|||
Revisions submitted on 9/23/21 all approved by building department, structural, drain location updates, and stage deletion of lighting and other items | |||
Utilities Review - Mt. Werner | Approved | 09/14/2021 | 08/30/2021 |
Malea Michael-Ferrier
|
|||
Richard approved addendum submitted 8.27.21 via email | |||
Building Code Review | Approved | 08/16/2021 | |
Todd Carr
|
|||
Addendum approved on 8/16/21 | |||
Planning Review | Approved w/ Conditions | 08/09/2021 | |
SysAdmin
|
|||
VP legacy plan review: Steamboat Planning sysadmin - Jul 7 2021 9:57AM - BK to review sysadmin - Jul 8 2021 3:03PM - Per BK: Planning has the following comments on the building permit: 1. Demonstrate compliance with the Conditions of Approval from the Development Plan. See attached. I see that LEED is proposed. 2. The permit includes level 01 and 02 which were not a part of the Development Plan and, as such, cannot be approved at this time. Site plan and paving plan does not match approved DP. Some drawings note that this building is not a part while other drawings include it. 3. Lighting – Provide photometric plan. Also, what are the changes from the approved DP that were mention in our meeting the other day? 4. Elevations- a. Show elevations/materials for 2nd story as depicted and approved in the DP. sysadmin - Jul 19 2021 4:35PM - Per BK: Approval for core and shell only per Building Department’s approval conditions. sysadmin - Aug 9 2021 1:41PM - Addendum received 8/9/2021 OK per BK | |||
Fire Code Review | Approved | 07/14/2021 | |
SysAdmin
|
|||
VP legacy plan review: Steamboat Fire Dept sysadmin - Jun 25 2021 4:01PM - Conditionally approved- pending resubmittal of site plan with access width, grade, turning radius, turnaround, and turnouts meeting Fire Dept. access requirements or if unable to meet requirements submittal of fire sprinkler and monitored fire alarm plans and permits. No inspections past foundation until the above is resolved.) www.steamboatsprings.net for details. sysadmin - Jul 14 2021 11:09AM - 7/9/21 The drawings with the fire truck movements are acceptable for our purposes. The Fire Marshal has asked that GC add those drawing to the plans that you submitted. | |||
Legacy Permitting Review | Approved | 07/12/2021 | |
SysAdmin
|
|||
VP legacy plan review: Mt Werner Water District sysadmin - Jun 15 2021 1:11PM - Hi Jon, In an effort to get you started on approval for the referenced building permits the follow items need to be addressed: 1. Fill out the attached Plant Investment Fee (Credit Form) for the original Gondola Building. After our review, these credits can be applied against the proposed improvements and fixtures for this SITE ONLY. Any leftover credits will go with the subject property and CAN NOT be applied to any other properties. 2. Complete the take off and fill out the attached Plant Investment fee form for the proposed structures and buildings. Supply back up information on take offs as needed to demonstrate quantity assumptions or questions. 3. Provide data on sheet 1A-P1-200 specifying water meter size (supplied by MWW and paid for by SSRC in PIF form). Provide/revise notes that the public water system must be protected from the fire suppression system with a Reduced Pressure (RP) backflow device. This is per CDPHE Regulations. Add an additional RP device on the domestic side also. It appears to be 3” diameter. Verify floor drain in proposed Meter and Riser Room is adequate to handle the discharges from these backflow devices. Review attached large meter installation diagram for integration and compliance as needed. Once these items are addressed we will be able to sign off on the subject building permits. Please call with any questions on this preliminary review. Regards, Richard sysadmin - Jul 6 2021 12:36PM - Jon and Jim, Attached are the PIF Water and Sewer fees for the referenced permit. Sarah and I have worked thru all the quantities and are in agreement on the final numbers. The credits shown herein will be carried forward to the other current projects. At this time, please pay the amount indicated for the new water meter fees only. Please stop in our offices with a check for the amount indicated and I will get this permit signed off. Regards, Richard sysadmin - Jul 12 2021 9:20AM - PIF fees paid 7/7/21 | |||
Legacy Permitting Review | Approved w/ Conditions | 07/10/2021 | |
SysAdmin
|
|||
VP legacy plan review: Routt Building sysadmin - Jun 15 2021 11:05AM - Plan review process started sysadmin - Jun 25 2021 4:14PM - Plan review letter sent to applicant sysadmin - Jul 10 2021 1:01PM - Rsubmittal covered all items and concerns, permit is approved for Underground work and the lower level of the Promenade Building to move forward, this project will required additonal reviews for all deferred submittals, and level 1 and level2 are not approved at this time for any work to move forward. Foundation and Shell of Lower Level Approved for Promnade Building | |||
Engineering Review | Approved | 07/06/2021 | |
SysAdmin
|
|||
VP legacy plan review: Steamboat Engineering Dept | |||
External Agencies Review | Approved | 07/06/2021 | |
SysAdmin
|
|||
VP legacy plan review: YVEA | |||
External Agencies Review | Approved w/ Conditions | 07/06/2021 | |
SysAdmin
|
|||
VP legacy plan review: Atmos Energy sysadmin - Jul 6 2021 11:30AM - 2# Systems will not be allowed unless proof of an appliance requiring a MINIMUM of over 7" W.C. is provided to Atmos Energy COrp for personnel review. Meter location must be approved by an Atoms Energy Corp employee during a mandatory site visit to be scheduled after foundation is in place. Meters will not be allowed under a shedding roofline or where overhanging snow is a danger to the meter set. | |||
Legacy Permitting Review | Approved | 07/06/2021 | |
SysAdmin
|
|||
VP legacy plan review: Routt Electrical Plan Review | |||
GIS Land Development Review | Approved | 06/17/2021 | |
SysAdmin
|
|||
VP legacy plan review: Steamboat Address | |||
Finance Department Review | Approved | 06/16/2021 | |
SysAdmin
|
|||
VP legacy plan review: Steamboat Finance Dept sysadmin - Jun 15 2021 11:03AM - City of Steamboat Springs Finance has approved City tax & permit fees of $508,325.77 on this permit. This is the City’s portion, made payable to the City of Steamboat Springs and submitted to the Routt County Regional Building Department. At the end of the project, City of Steamboat Springs Finance requires a construction use tax reconciliation be completed to be compliant with the City of Steamboat Springs Municipal Code AND prior to signoff for the FINAL certificate of occupancy/approval with the Routt County Building Department. |
Inspection | Outcome | Requested | Scheduled | Date Inspected |
---|---|---|---|---|
Footing Inspection | Complete | 08/11/2021 | ||
SysAdmin | ||||
Footing Inspection | Partial Pass | 8/20/2021 | 8/20/2021 | 08/20/2021 |
Don Marchbanks | ||||
Footing Inspection | Partial Pass | 8/27/2021 | 8/27/2021 | 08/27/2021 |
Don Marchbanks | ||||
Foundation Inspection | Partial Pass | 9/7/2021 | 9/7/2021 | 09/07/2021 |
Don Marchbanks | ||||
Footing Inspection | Partial Pass | 9/9/2021 | 9/9/2021 | 09/09/2021 |
Don Marchbanks | ||||
Foundation Inspection | Partial Pass | 9/20/2021 | 9/20/2021 | 09/20/2021 |
Todd Carr | ||||
Foundation Inspection | Partial Pass | 9/23/2021 | 9/23/2021 | 09/23/2021 |
Don Marchbanks | ||||
Footing Inspection | Partial Pass | 10/6/2021 | 10/6/2021 | 10/06/2021 |
Don Marchbanks | ||||
Foundation Inspection | Partial Pass | 10/8/2021 (2:00 to 3:00) | 10/7/2021 | 10/08/2021 |
Don Marchbanks | ||||
Foundation Drain Inspection | Partial Pass | 11/3/2021 | 11/3/2021 | 11/03/2021 |
Todd Carr | ||||
Structural Inspection | Partial Pass | 11/5/2021 | 11/5/2021 | 11/05/2021 |
Todd Carr | ||||
Structural Inspection | Partial Pass | 11/9/2021 | 11/9/2021 | 11/09/2021 |
Todd Carr | ||||
Structural Inspection | Partial Pass | 11/16/2021 | 11/16/2021 | 11/16/2021 |
Todd Carr | ||||
Framing Inspection | Partial Pass | 12/15/2021 | 12/15/2021 | 12/16/2021 |
Todd Carr |
Condition | Status | Category |
---|---|---|
Miscellaneous Conditions | Open | Prior to Rough Building Wall Inspections |
Fire Prevention
Conditionally Approved – pending deferred submittal of alarm and sprinkler plan/permits by sub-contractor to Fire Prevention. See www.steamboatsprings.net
|
Reference Number | Status | Type |
---|---|---|
SPRMH210083 | Closed | Mechanical |
SPREL210226 | Closed | Electrical |
SPRMH210396 | Closed | Mechanical |
SPRPL210563 | Closed | Plumbing |
SPRNR220115 | Closed | New Commercial Building |
SPRMH221078 | Closed | Mechanical |
SPREL221341 | Closed | Electrical |
SPRMH221729 | Closed | Mechanical |