City of Steamboat Springs Web Portal

Permit Application Status

SPRFO240628


In order to view fees, you need to be signed in. You will only be able to schedule inspections if you are a contact on the permit application.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

SPRFO240628
Foundation Repair/Retaining Wall/Tower/Light Pole/Abutment
Permit(s) Issued
STEAMBOAT GRAND RESORT HOTEL
New
Two new retaining walls along the driveway for 'The Amble' project located at 2300 Mt Werner Circle. The first approximately 225ft long and 6' high. The Second approximately 150ft long and 6' high.
05/31/2024
06/24/2024
06/24/2027

Locations

Property
218177001

Address
2300 MT WERNER CIR

Permits

Permit Number: SPRFO240628-FD1

Foundation
Issued

Reviews

Documents Returned For Corrections

Review Type Outcome Est. Completion Date Completed
Fire Code Review Approved 06/17/2024 06/21/2024
Construction Site Management Review Approved 06/17/2024 06/17/2024
Utilities Review - Mt. Werner Approved 06/17/2024 06/14/2024
Building Code Review Approved 06/17/2024 06/14/2024
Planning Review Approved 06/17/2024 06/12/2024
Finance Department Review Approved 06/17/2024 06/04/2024

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Foundation/Under Slab Insulation Pending
Footing Inspection Pending
Foundation Inspection Pending
Water Service Inspection Pending
Amber Gregory
Sewer Service Inspection Pending
Amber Gregory
Interim Construction Site Management Pending
Scott Slamal
Final Construction Site Management Pending
Scott Slamal
Foundation Water Proofing Pending
Radon Piping Pending
Foundation Drain Inspection Pending
Structural Inspection Pending
Foundation Drain Inspection Partial Pass 8/20/2024 8/20/2024 08/20/2024
Ron Norton
Structural Inspection Not Ready 8/21/2024 8/21/2024 08/21/2024
Ron Norton

Conditions

Condition Status Category
Use Tax Reconciliation Open Prior to Issuance of CO/CC
Finance
Use Tax Reconciliation
Building Department Conditions to be Completed Open Prior to Final Building Inspection
Building Department
The reqeusted special inspection report by the Soil Strucutres Engineer of Record Item 2.3 on sheet RW-2.00 shall be uploaded to the CityView Portal once the Soil Engineer has recieved and signed approval all backfill to be placed. In addition please upload a final conformance letter for from the compancy completeing all special inspections on this project beyond Item 2.3, so the Building Department can retain a copy for your records. Both reporst must be recieved prior to our final inspection being scheduled.
Miscellaneous Conditions Resolved
Mount Werner Water & Sanitation
Miscellaneous Conditions

Related Permit & Planning Applications

There are no related items for this permit application.

Documents & Images

Date Uploaded File Type Name
Letter INCOMPLETE APPLICATION NOTICE.PDF
Report INSPECTION REPORT.PDF
Report INSPECTION REPORT.PDF
Letter PERMIT - DETAILED.PDF
Receipt RECEIPT.PDF
Receipt RECEIPT.PDF
06/21/2024 Study Soils Report - The Amble (Received) (Stamped)
06/21/2024 Plans Site Plan (Stamped)
06/21/2024 Retaining Wall Plans (Stamped)
06/21/2024 Retaining Wall Calculations (Stamped)