| Inspection | Outcome | Requested | Scheduled | Date Inspected |
|---|---|---|---|---|
| Plumbing Final Inspection | Failed | 12/20/2021 | 12/20/2021 | 12/20/2021 |
| Todd Carr | ||||
|
Corrections:
Miscellaneous
Carried Forward
12/20/2021
Plumbing Final has corrections, need to run cast iron pipe through the concrete floor/ceiling of the parking garage, currently has pvc for main drain and vent, replace with cast iron, then seal up with concrete and fire caulk around cast iron.
|
||||